Charging Controller Description
Supply voltage: 12V ± 5%
Power consumption: < 5W
Operating temperature: -40 to +80°C
Dimensions (L-W-H): 125-90-40(mm)
Controller Features:
- 1 galvanically isolated RS485 interfaces
- 2 galvanically isolated digital inputs
- 4 relay (5A) for implement direct function, 2 relay (5A) for direct actuator
Operating Modes:
The controller is designed for use as part of an electric charging station. It supports the AC charging standard IEC 61851, GB/T 18487.
The controller can independently control the power modules and also act as a slave device. Control of the power modules is delegated to the central controller. This mode is required for stations with power balancing.
Communication Protocol:
The primary control protocol is Modbus RTU. The register map can be modified upon customer approval.
Typical Connection Diagram
Structural Diagram of the Controller:
Need a Type2 controller?
We offer Type2 AC controllers with Mode 3 signaling, lock control, and grid-friendly features ready for deployment.